Uneven Flow Distribution
Troubleshooting

Uneven Flow Distribution

Some Plates Overloaded, Others Starved

When flow is not shared evenly across all plates, part of the pack is hydraulically overloaded and carries over solids while the rest is under-used — cutting effective capacity.

Understanding the Problem

The inlet distribution system exists to feed every plate channel equally. Poor design, partial blockage or asymmetric piping concentrates flow, so the effective surface loading rate is far higher than the average in the loaded zone.

Because the average loading looks acceptable, uneven distribution is often missed — yet it is one of the most common reasons a correctly sized unit under-performs.

Inspect the distributor, baffles and inlet geometry; dye or float testing quickly reveals the flow pattern.

Common Symptoms

  • Carryover from one area only
  • Visibly faster flow in some channels
  • Capacity below nameplate
  • Uneven sludge distribution

Causes & Corrective Actions

Cause

Poor inlet / distributor design

Corrective Action

Redesign inlet baffling for uniform feed across the pack.

Cause

Partial blockage of distributor

Corrective Action

Clean the distribution system; add upstream screening.

Cause

Asymmetric inlet piping

Corrective Action

Add flow-splitting baffles or a distribution channel.

Cause

Unlevel installation

Corrective Action

Check and correct level of the vessel and weirs.

Prevention

Validate distribution at commissioning
Keep distributor clear
Level installation and weirs
Periodic dye/flow checks