Plate Settler Sizing Calculator
Interactive Tool

Plate Settler Sizing Calculator

Estimate Settling Area, Plate Count & System Series

Enter your design flow and target surface loading rate to get a preliminary plate settler sizing and a recommended R+F system series. For a validated design, send us your data for a free engineering review.

Your Inputs

m³/h
m/h
°
m
m

Preliminary Results

Required Settling Area

40.0

m² (projected)

Estimated Plate Count

35

plates @ 1.15 m² each

Recommended System Series

R+F PSH / PSXHigh-Rate or Containerized

High-rate performance or plug-and-play containerized delivery.

Request a validated sizing

These results are a first-order estimate based on the classic A = Q / SLR relationship and projected plate area A_plate = L × W × cos(θ). Actual designs account for plate spacing, hydraulic distribution, sludge handling, temperature, coagulation/flocculation and a safety factor. Always confirm with R+F engineering before procurement.

Request an Engineering Assessment

Our engineers will review your application, flow rates, and water quality data to recommend the optimal plate settler configuration.